Federal Pacific "Stab-Lok" Panels


Federal Pacific Electric "Stab-Lok" service panels and breakers are a latent hazard and can fail, leading to electrical fires. The problem is that some double-pole (240-Volt) FPE circuit breakers and possibly also some single-pole units simply may not work. We also have reports that independent of the breaker problems, there have been panel and panel-bus fires and arcing failures in some equipment.

A latent hazard exists where FPE Stab-Lok circuit breakers continue in use. The hazard is worst for double-pole breakers. Published reports of actual tests that were performed indicate that under certain conditions it is possible for one leg of these circuits to attempt to trip the breaker, resulting in a jammed breaker which will afterward not trip under any load condition.

Some common household appliances are powered by a two-pole 240V circuit (protected by the type of breaker under discussion) but use two or more independent 120V sub-circuits inside the appliance. Two obvious cases are electric clothes dryers and ranges. If, for example, the low-heat (110V) heater in a dryer were to short to the dryer case, a serious overcurrent would occur on one "leg" of the circuit.

Another wiring practice, using a single two-pole breaker to power a split circuit which uses a shared neutral, such as may be installed in kitchens in some areas, is nearly certain to have each leg of the circuit loaded independently and thus subject to single-leg overloading and subsequent breaker jamming. A breaker which jams and then fails to trip under this condition is a serious fire hazard.

These panels are easy to identify.They usually display the FPE and/or the "Stab-Lok" logos / insignia. Typically a knowledgeable electrician will recommend replacing these panels. Replacement cost is usually about $1000.00.





Click Here to read more on our Hot Topics:
  1. Aluminum Wiring
  2. Asbestos
  3. E.I.F.S. aka Synthetic Stucco
  4. Federal Pacific "Stab-Lok" Panels
  5. Mold
  6. Polybutylene Plumbing




© Copyright 2008 AccuSpec Inspections All Rights Reserved.
For more information please Contact US.

Find Virginia Beach Home Inspections,  Find Home Inspectors Chesapeake Virginia,   Find Home Inspectors Hampton Virginia,   Find Newport News Virginia Home Inspections,   Find Norfolk Virginia Home Inspections,   Find Find York County Virginia Home Inspections,   Find Portsmouth Home Inspections,   Find Suffolk Home Inspections,   Find York County Virginia Home Inspections